FY2020 Number of assessment from Domestic Operating Experience

(2020.3.15~2021.3.20)

NUCIA Classification Number Significance
A+ A B++ B+ B! B a+ a b++ b+ b! b C D
Trouble Information 7     1 --   3   1   -- -- 2 -- --
Maintenance Quality Information 80     1 1   43   --   2 2 31 -- --
Other Information 98 -- -- -- -- -- 1 -- -- -- -- -- 10 37 50
total 185     2 1   47   1   2 2 43 37 50
1. Event needs extent of condition
Significance Information sharing
(Significant event)
Information sharing
(Event)
A+ A B++ B+ B! B
Category Significant event occurring repeatedly
(Recurrent significant event)
Event having significant influence on nuclear safety
(Significant Event)
Recurrent
event occurring repeatedly
(Event recurring significant recurrent )
Recurrent monitoring
Event having possibility
to recur
(Recurrent event)
Alerted
event having
possibility to recur
similar events
(Alerted recurrent event)
Other of A+ ~ B! event although it needs extent
of condition
NUCIA Classification In principle, Trouble information (T-information), Maintenance quality information (M-information)
2. Event does not need extent of condition
Significance Information sharing (Significant event) Information sharing (Event) Reference information -
a+ a b++ b+ b! b C D
Category Significant event occurring repeatedly
(Recurrent significant event)
Event having significant influence on nuclear safety
(Significant Event)
Recurrent event occurring repeatedly
(Event recurring significant recurrent )
Recurrent monitoring Event having possibility to recur
(Recurrent event)
Alerted event having possibility to recur similar events
(Alerted recurrent event)
Other of a+ ~ b! event although it needs extent of condition Reference information although it does not need extent of condition Event having no lesson
NUCIA Classification In principle, Trouble information (T-information), Maintenance quality information (M-information) Other information
(S-information)